LiftMaster Security+ 2.0 LED Diagnostic Blink Code Reference

Up / Down Arrow Blinks LiftMaster Fault Description Field Repair Procedure
1 Up · 1 Down (or 10 Flashes) Safety reversing sensors disconnected or open circuit Inspect white/black bell wire at terminal block; splice broken staple cut or replace photo-eyes (Sensor Repair →)
1 Up · 2 Down Safety sensor low-voltage wires shorted or reversed Ensure white-to-white and white/black-to-grey terminal polarity; clear pinched staple short
1 Up · 3 Down Door control wall console shorted or faulty Test red/white terminal voltage; replace shorted 880LMW / 889LM smart control panel (Wall Switch →)
1 Up · 5 Down Motor RPM encoder fault OR 8500W Cable Tension Monitor open Check for broken torsion spring first; on 8500W/98022 jackshafts, verify green cable roller switch is closed
3 Up · 5 Down Automatic Garage Door Lock (841LM deadbolt) binding Enlarge or realign vertical track bolt hole so power deadbolt slides without friction
4 Up · 1–4 Down Door hit physical obstruction or broken spring overload Perform manual balance test; replace broken torsion spring or realign binding track (Opener Repair →)
4 Up · 6 Down (10 Blinks) Photo-eye beam misaligned, fogged, or blinded by sun glare Align green receiver LED solid, swap emitter/receiver sides away from afternoon sun, install sun hoods